Labsyntha logolabsyntha.Join a pilot→
DESIGN STAGE, PILOT LABS WANTED

Lab data you can trace back to the instrument.

Labsyntha keeps every instrument file exactly as it arrived, cleans it in steps that can be replayed, uses machine learning to flag measurements a scientist should check, and records each decision in a log that shows tampering.

PLATE-0042 / run 183 flagged wells
D4 outlier vs replicatesreview
H7 drift vs plate medianreview
A8 edge effectreview
Illustrative data
01
Stage
Design
02
Pilot
Recruiting 2 or 3 labs
03
Benchmarks
None published yet
04
Regulated use
Later phase
Approach

The result is only as good as its history

In a small lab, instrument exports are copied, renamed and edited by hand. When a number reaches a figure, nobody can say which file it came from or who changed it.

Shared folder: Assay results
results.xlsx
results_final.xlsx
results_final_v2.xlsx
results_final_v2_edited.xlsx
results_final_v2_edited_USE_THIS.xlsx
Which one produced Figure 2?

Three rules we build around

01

The original file never changes.

It is stored as received and addressed by its hash.

02

Every later step is a recorded transformation.

A result can be rebuilt from the raw file by replaying the steps.

03

Models suggest and people decide.

A flag is a prompt for review, and the decision is logged with the reviewer’s name.

Platform

Architecture

Services that touch data run on CPU. Image models and batch re-scoring run in a separate GPU pool, so interactive screens never wait for a model.

CPU SERVICESInstrumentsreader, qPCR, imagerIngestparse, validateRaw storefiles, by hashPostgreSQLevents, recordsNormalize + featuresUCUM units, replicatesGPU inference poolversioned model endpointsReview UI + APIaccept, reject, export
01

Ingestion

Every instrument file is stored exactly as received and addressed by its SHA-256 hash. Vendor-specific parsers convert each file into typed records, and each record is validated against a versioned schema before it is written. Ingestion is idempotent, so uploading the same file twice creates no duplicate records.

Raw store: object storage, content addressed
Parsers: one per instrument format, versioned
Validation: JSON Schema on every record
02

Normalization

Measurements map to one model of sample, container, well, measurement and unit. Units follow the UCUM standard, and every conversion is an explicit function whose name and version are stored with the result. Replicates are grouped from the protocol definition, never inferred from well position.

Model: sample, container, well, measurement, unit
Units: UCUM, conversions recorded
Replicates: defined by protocol
03

Detection

Detection starts with robust statistics so a lab gets useful flags before any model is trained, then adds learned detectors. Each flag stores the method and the version that raised it, and the table below lists what we plan to build and in what order.

Score: precision and recall per lab
Drift: population stability index on inputs
Release rule: no model ships without a published score
04

Audit and provenance

Every change is an event in an append-only log, and each event stores the hash of the one before it, so an edit to history is detectable. A provenance graph links the raw file, parser version, normalized record, model version and the person who accepted or rejected each flag.

Log: append-only, hash chained
Provenance: raw file to decision, queryable
Export: full history in open formats
event n-1hash = H(n-1)event nprev = H(n-1)event n+1prev = H(n)
05

Security

Each lab is a separate tenant, enforced with row-level security in PostgreSQL. Data is encrypted in transit and at rest, access is role based, and exports are signed so a recipient can verify them. 21 CFR Part 11 is a later phase, and the log is designed so it can be added without a rewrite.

Isolation: row-level security per tenant
Access: role based
Exports: signed
Models and compute

What runs on GPUs, and why

Four components, built in this order. Each one has to beat the simpler one before it on a labelled review set, or it does not ship.

ComponentMethodInputHardwareStatus
Replicate outlier flagMedian and median absolute deviation on replicate groupsWell valuesCPUDesign, first to build
Run-level anomaly detectorIsolation-based model on per-run features such as control wells, signal range and edge-to-centre ratioRun summariesCPU for training, GPU optionalDesign
Plate and gel image qualityConvolutional network fine-tuned from a pretrained backboneScan imagesNVIDIA GPU for training and batch inferenceDesign
Lab note structuringSmall language model that extracts reagent, lot and deviation fields, always reviewed by a personFree-text notesGPU inferenceResearch

Where GPUs earn their place

Image models need them for training and for scoring many scans quickly. Batch re-scoring needs them when a model improves and a lab's whole backlog has to be checked again. Large table operations on multi-million row measurement sets use RAPIDS dataframes. Everything interactive stays on CPU, so cost follows the workload.

Models sit behind versioned endpoints in a registry. A new version first runs on one lab, and a rollback is a configuration change.

out of focus
Illustrative layout, not real output

How we will evaluate

We have no benchmark results yet. After the first pilot we will publish the method, the size of the labelled set, and precision and recall, including the cases where the models were wrong.

01

Labels from real review

Scientists mark wells good or bad during normal review. Each label stores the reviewer and the time.

02

Split by run

Neighbouring wells share signal, so random splits leak. We hold out whole runs, and later whole labs.

03

Report the cost

Precision, recall and false flags per plate, because reviewers feel every false flag.

04

Watch for drift

Alerts when instruments or reagents change. Retraining is a reviewed release, not a background job.

Inputs

What we plan to read, and in what order

We will not list an instrument vendor until a parser has been tested on real files from that vendor.

Phase 1

Plate reader exports

CSV and XLSX exports, with one versioned parser for each layout.

Phase 2

qPCR run files

Run exports with amplification and melt curves, kept as raw series.

Phase 2

Spreadsheets and sample lists

Bulk import of existing results, with every imported row marked as imported.

Phase 3

Plate and gel images

PNG and TIFF scans, used by the image quality model.

API

Ask any result where it came from

One call returns the raw file hash, every transformation with its version, each flag with the method that raised it, and who accepted or rejected it. A reviewer, a collaborator or a journal can check a number without access to the lab's folders.

This is the planned shape of the API. It will change as pilot labs use it.

GET/v1/results/R-18204/provenance
{
  "result_id": "R-18204",
  "value": 12.4,
  "unit": "ng/uL",
  "raw_file": {
    "sha256": "9f2c...",
    "received": "2026-11-17T09:41:12Z"
  },
  "steps": [
    {"op": "parse", "version": "plate_reader_csv@0.3.1"},
    {"op": "normalize", "version": "units@0.2.0"}
  ],
  "flags": [
    {"method": "replicate_mad", "version": "0.1.0",
     "status": "rejected", "reviewer": "u-0007"}
  ],
  "log_seq": 18204
}
Illustrative values
Roadmap

Four phases, each with an exit test

  1. 01Phase 1

    Ingestion and audit log

    Parsers for one instrument family, content-addressed storage, hash-chained log.

    Exit: a pilot lab finishes its runs with no hand-edited result files.

  2. 02Phase 2

    Normalization and review

    Canonical data model, UCUM units, review screen with accept and reject.

    Exit: every final value traces back to a raw file.

  3. 03Phase 3

    Detection

    Statistical flags, run-level detector, image quality model, evaluation report.

    Exit: published precision and recall on held-out runs.

  4. 04Phase 4

    Scale and compliance

    Second assay type, public API, groundwork for Part 11.

    Exit: a second lab joins with no schema changes.

PRODUCT WALKTHROUGH VIDEO
Three minutes, file upload to flagged well to audit entry
1920 x 1080
Team

Four people, one traceable record

Johnson Gabriel, CEO and founder

Johnson Gabriel

CEO and founder

Leads the company and the relationships with pilot labs.

Ameh Adah, Chief technology officer

Ameh Adah

Chief technology officer

Owns the platform architecture and the data pipeline.

Eric Obi, Head of machine learning and developer

Eric Obi

Head of machine learning and developer

Builds the detection models and the evaluation, and writes code across the stack.

Kizito Olofu, Lab science advisor

Kizito Olofu

Lab science advisor

Advises on assay design and on what a reviewer needs to see.

Built with NVIDIA CUDA and RAPIDS, PyTorch, PostgreSQL, FastAPI and React. These are tools we use, not partnerships. Product names belong to their owners.

FAQ

Questions a lab will ask

Does a lab need its own GPUs?

No. Statistical flags and all interactive screens run on CPU. Image models and batch re-scoring run in a GPU pool that we plan to host, so labs do not buy hardware.

Who owns the data?

The lab. Raw files are kept as received, and everything exports in open formats at any time.

What happens when a model is wrong?

Models only flag. A person accepts or rejects each flag, both outcomes are logged, and rejected flags become labelled examples for the next evaluation.

Is it ready for regulated work?

Not yet. GxP and 21 CFR Part 11 are a later phase. The audit log is designed so that adding them does not need a rewrite.

Which assay type comes first?

Our first release targets one assay type, and we are choosing it together with the first pilot lab.